Die Casting Machine Tonnage & Shot Sleeve Fill Calculator
"Can this machine run the job?" is really two questions: is the clamp force enough, and does the shot sleeve hold the shot? Get the first wrong and you flash or blow the die apart; get the second wrong and the shot bottoms out before the cavity fills. Both scrap the whole die. This tool answers both, then names the standard machine size and tells you whether the fill ratio sits in a workable window.
1. Clamp force and machine tonnage
| Total projected area (all cavities) | — cm² |
| Theoretical clamp force | — kN |
| Design clamp force (with safety factor) | — t |
| Clamp force of selected machine | — kN |
| Machine utilisation | — % |
| Next size up | — t |
2. Shot sleeve fill ratio
Fill ratio is the metal volume one shot needs divided by the usable volume of the shot sleeve. Too small a sleeve and the plunger bottoms out before the cavity is full; too large a sleeve and the trapped air turns into porosity and oxide inclusions. General-purpose work sits between 40% and 80%.
—
| Usable sleeve volume | — cm³ |
| Metal volume per shot | — cm³ |
| Biscuit weight | — g |
| Shot weight (pour weight) | — g |
| Remaining sleeve volume | — cm³ |
±20%. The projected area must include runners, overflow and air vents — on thin-wall aluminium parts that is easily a third of the total. Specific pressure moves with alloy, wall thickness and leak-tightness requirements. This tool checks clamp force and sleeve volume only; it does not check die opening stroke, tie-bar spacing, ejection force or die thickness — a machine can have plenty of tonnage and still not accept the die.
Formulas
Clamp force (kN) = projected area (cm²) × specific pressure (MPa) × 0.1 × safety
Sleeve volume (cm³) = π/4 × bore² (mm²) × stroke (mm) ÷ 1000
Metal volume = casting volume × (1 + runner share) + biscuit volume
Fill ratio (%) = metal volume ÷ sleeve volume × 100 The 0.1 factor is unit conversion: 1 MPa = 1 N/mm² = 100 N/cm² = 0.1 kN/cm². One tonne of clamp force is about 9.81 kN, so 1656 kN is roughly 169 t.
Worked example
120 cm² projected area including overflow, 2 cavities, aluminium at 60 MPa, safety 1.15:
| Total projected area | 120 × 2 = 240 cm² |
| Theoretical clamp force | 240 × 60 × 0.1 = 1440 kN |
| Design clamp force | 1440 × 1.15 = 1656 kN ≈ 168.9 t |
| Recommended machine | 200 t (1961 kN clamp), utilisation 73% |
| Same part in zinc at 40 MPa | 960 kN → 1104 kN design ≈ 112.6 t → 160 t machine |
| Four cavities instead of two | 2880 kN → 3312 kN design ≈ 337.7 t → 400 t machine |
Sleeve: 60 mm bore, 400 mm stroke, 25 mm biscuit, 380 cm³ casting, 25% runners, aluminium at 2.7 g/cm³:
| Sleeve volume | π/4 × 60² × 400 ÷ 1000 = 1130.97 cm³ |
| Biscuit volume | π/4 × 60² × 25 ÷ 1000 = 70.69 cm³ |
| Metal volume per shot | 380 × 1.25 + 70.69 = 545.69 cm³ |
| Fill ratio | 545.69 ÷ 1130.97 = 48.25% (inside the window) |
| Shot weight | 545.69 × 2.7 ≈ 1473 g |
Specific pressure is not intensification ratio
Quotes often mix the two. Specific pressure (MPa) is the metal pressure acting on the projected area and it sets the clamp force. The intensification ratio is the ratio of shot force after the intensifier fires to the force before it, and it decides whether the last bit of feed metal gets pushed in before the gate freezes. This calculator handles the first. The second depends on the shot cylinder area, accumulator pressure and intensifier setting — machine parameters you cannot derive from part geometry.
The three fill ranges
- Below 40% — too much air in the sleeve. Air entrainment, broken oxide film and unstable shot velocity; thin sections cold-shut.
- 40%–80% — the normal window. When changing sleeves, pick the bore that lands here rather than stretching the stroke to its limit.
- Above 80% — vents can't keep up, flash grows, the biscuit gets too thin to feed. Above 100% the shot simply does not fit: use a larger sleeve or fewer cavities.
Four common mistakes
- Projected area of the part only — runners, overflow and vents routinely add 15%–35% on aluminium, which is exactly one machine size.
- Using the hydraulic gauge pressure — gauge pressure and cavity metal pressure differ by the shot cylinder to plunger area ratio.
- Forgetting cavities — two cavities double both the projected area and the clamp force.
- Checking tonnage but not the sleeve — plenty of tonnage with too small a sleeve gives short shots, and reworking that costs more than renting the next machine size.
Not included
- Shot velocity profile, intensification time and die vent area — these need a trial run.
- Die opening stroke, tie-bar spacing, die thickness and ejection force.
- Vacuum die casting, semi-solid and squeeze casting specifics.
- Piece cost: use the die casting cost calculator for that. This page only answers "which machine".
FAQ
Utilisation is only 73% — why not the next size down?
Machine sizes are discrete. A 168.9 t design clamp rounds up to the nearest 200 t machine; a 160 t machine clamps at 1569 kN, below the 1656 kN required, and will flash. Below 50% utilisation the better move is to change cavity count or machine series, not to force a bigger press.
Why do zinc parts need less tonnage?
Zinc flows well and needs only 30–50 MPa specific pressure, so clamp force is roughly half to seventy percent of an aluminium part of the same size. But zinc is 6.6 g/cm³, so the same sleeve holds more than twice the shot weight — check sleeve capacity separately.
Does a good fill ratio guarantee good castings?
No. Fill ratio only says the shot fits and the sleeve is not mostly air. Shot velocity, venting, die temperature and die release agent decide porosity and cold shuts, and only a trial run plus X-ray confirms those. This tool's job is to rule out machines that clearly cannot run the job at the quotation stage.